Low voltage cabinet GGS
model:
- Commodity name: Low voltage cabinet GGS
- Product Description
-
Product overview
GGS low-voltage drawer switchgear is widely used in power distribution centers of power plants, substations, industrial enterprises, and high-rise buildings, as well as in motor control centers (MCC). It serves as a low-voltage complete distribution device for centralized control of power distribution and motor operation in AC systems operating at 50-60Hz, with rated voltages up to 660V and rated currents up to 4000A. It is also used for reactive power compensation.
Main technical parameters
Rated insulation voltage: AC 660V, AC 1000V
Rated working voltage: AC 380V, AC 660V
Rated frequency: 50Hz
Rated current of horizontal busbar: 1250~4000A
Rated current of vertical busbar: 1000A
Maximum current of power supply circuit: 2500A
Maximum current of drawer circuit: 500A
Maximum capacity of control motor: 320KW
Peak withstand current of horizontal busbar (0.1S): 63KA, 105KA, 176KA
Horizontal bus short time withstand current (1S): 30 KA, 50 KA, 80 KA, 100 KA Vertical bus peak withstand current (0.1S): 63 KA, 105 KA
Vertical bus short time withstand current (15): 30 KA, 50 KA rated power frequency withstand voltage (1min): 2500V
Secondary power frequency withstand voltage (1min): 2500V
Protection class: IP30, IP40
External dimensions width * depth * height mm: 600 (800,1000) *800 (1000) *2200
Product use environment
1. The ambient air temperature shall not be higher than +40℃ and lower than-5℃, and the average temperature within 24h shall not be higher than +35℃. If it exceeds the limit, the operation shall be reduced according to the actual situation;
2. Indoor use: the altitude of the place where it is used shall not exceed 2000m;
3. When the relative temperature of the surrounding air is +40℃, it should not exceed 50%. At a lower temperature, a larger relative temperature is allowed, such as +20℃, which should be 90%. The influence of condensation may occur occasionally due to the change of temperature should be taken into account;
4. The slope of the device installation to the vertical plane shall not exceed 5℃, and the whole cabinet column shall be relatively flat (in line with GBJ232-82 standard);
5. The device shall be installed in a place without violent vibration and impact, and not enough to cause undue corrosion of electrical components;
6. If the user has special requirements, it can be negotiated with the manufacturer.