Contact Us
Email:laicaieven@gmail.com
WhatsApp:+86 17710715268
Address:516, 5th Floor, Building 4, No. 7 Guangyang New Road, Fangshan District, Beijing
High voltage cabinet HXGN □-12
model:
- Commodity name: High voltage cabinet HXGN □-12
- Product Description
-
Overview
The HXGN□-12 Box-type AC Metal-Enclosed Ring Main Switchgear is a new generation of high-voltage electrical products designed and developed by our factory, incorporating advanced foreign technologies and tailored to China's power supply requirements. It is suitable for urban grid renovation and construction needs. The performance meets the standards of IEC298 "AC Metal-Enclosed Switchgear and Control Equipment" and GB3906 "3~35kV AC Metal-Enclosed Switchgear." It is applicable to three-phase AC systems in factories, schools, residential areas, and high-rise buildings with system voltages of 3~10kV and rated frequencies of 50Hz, used for receiving and distributing electrical energy. It can be used for ring main power supply and terminal power supply.
Product based on standards
GB3804 3~63kV AC high voltage load switch GB3906 3~35kV AC metal closed switchgear GB11022 General technical conditions for high voltage switchgear GB9969.1 General instructions for use DL404 Technical conditions for ordering indoor AC high voltage switchgear IEC420 A combination of high voltage AC load switch and fuse Conditions of use
1, ambient temperature: maximum temperature +40℃; minimum temperature-15℃;
2. Relative humidity: the daily average value is not greater than 95%; the monthly average value is not greater than 90%
3. Altitude: not higher than 1000m
4. The intensity of the earthquake should not exceed 8 degrees
5, saturated steam pressure: the daily average value is not greater than 2.2x10-3Mpa; the monthly average value is not greater than 1.8x10-3Mpa
6. Places without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.
7. Special use conditions (areas beyond the normal use environment mentioned above) should be negotiated with the manufacturer when ordering
Technical parameters
Order number Rated voltage Unit Distribution conforms to switch and combination electrical-ISARC1 Distribution conforms to switch and combination electrical-ISARC2 1 rated voltage kV 12 12 2 rated frequency Hz 50 50 3 Rated current of main bus A 630 630 4 Rated short time withstand current kA/s 20/2 - 5 Rated peak withstand current kA 50 - 6 Rated short circuit closing current kA 50 - 7 Rated active load breaking current A 630 - 8 Rated closed loop breaking current A 630 - 9 No-load transformer kVA - 1600 10 Rated cable charging current A 10 10 11 Rated short circuit breaking current kV - 31.5 12 Rated switching transfer current A - 3150 13 Power frequency withstand voltage (1min) kV Alternately, relatively: 42, between isolation breaks: 48 - 14 Lightning impulse withstand voltage kV Alternately, relatively: 75, between isolation breaks: 85 (peak) - Order instructions
1. Product name, model, primary line scheme and quantity
2. Name, model and specification and quantity of electrical equipment installed in the vacuum ring network cabinet
3. Arrangement diagram, plan layout diagram and secondary schematic diagram of vacuum ring network cabinet
4. The material specifications of the main busbar and branch busbar can be proposed by the customer, or supplied according to the manufacturer's standard if there is no requirement
5. Special requirements for cabinet color shall be negotiated with the manufacturer (if no requirements are required, the manufacturer's standard shall be supplied)
Keywords:
High voltage cabinet
Get Quote