Submit Message

SC (B) 10,11- □/□ series resin insulated dry transformer

Resin-insulated dry-type transformers are developed by our company through the introduction of advanced foreign technology and independent research. We have developed the SC9, SCB9 series, as well as the SC10 and SCB10 series of dry-type transformers. Due to the coils being encapsulated in epoxy resin, these transformers are flame-retardant, fireproof, explosion-proof, maintenance-free, non-polluting, compact, and can be installed directly at load centers. The scientific and rational design and casting process ensure that the product has lower partial discharge, low noise, strong heat dissipation capabilities, and can operate for long periods under forced air cooling conditions at 125% rated load. Equipped with an intelligent temperature controller, it features fault alarms, over-temperature alarms, over-temperature tripping, and black box functions. It also connects to a computer via a RS485 serial interface for centralized monitoring and control.

model:

  • Commodity name: SC (B) 10,11- □/□ series resin insulated dry transformer

Phone:

  • Product Description
  • Product features

    Resin-insulated dry-type transformers are developed by our company through the introduction of advanced foreign technology and independent research. We have developed the SC9, SCB9 series, as well as the SC10 and SCB10 series of dry-type transformers. Due to the coils being encapsulated in epoxy resin, these transformers are flame-retardant, fireproof, explosion-proof, maintenance-free, non-polluting, compact, and can be installed directly at load centers. The scientific and rational design and casting process ensure that the product has lower partial discharge, low noise, strong heat dissipation capabilities, and can operate for long periods under forced air cooling conditions at 125% rated load. Equipped with an intelligent temperature controller, it features fault alarms, over-temperature alarms, over-temperature tripping, and black box functions. It also connects to a computer via a RS485 serial interface for centralized monitoring and control.

    Because of the above characteristics of our company's dry transformers, they are widely used in power transmission and transformation systems, such as hotels, airports, high-rise buildings, commercial centers, residential areas and other important places, as well as subways, smelting, power plants, ships, offshore drilling platforms and other harsh environments.

     

    Model meaning

     

    Technical parameters of SC(B)9

    Rated capacity (kVA)

    Voltage combination (kV)

    Low pressure

    Connection method

    Loss (kW)

    No-load current (%)

    Impedance voltage (%)

    Noise dB(A)

    High-handed

    Carrying idler

    Load (120°C)

    30

    11、10.5、10、6.6、6.3、6

    0.4、0.69、1.14、1.2

    Dyn11 or Yyn0

    0.22

    0.75

    3.2

    4

    63

    50

    0.31

    1.06

    2.8

    63

    80

    0.42

    1.460

    2.6

    65

    100

    0.45

    1.67

    2.4

    65

    125

    0.53

    1.96

    2.2

    66

    160

    0.61

    2.25

    2.2

    66

    200

    0.70

    2.68

    2.0

    67

    250

    0.81

    2.92

    2.0

    67

    315

    0.99

    3.67

    1.8

    69

    400

    1.10

    4.22

    1.8

    69

    500

    1.31

    5.17

    1.8

    70

    630

    1.46

    6.31

    1.6

    6

    71

    800

    1.71

    7.36

    1.6

    72

    1000

    1.99

    8.61

    1.4

    72

    1250

    2.35

    10.26

    1.4

    74

    1600

    2.76

    12.42

    1.4

    75

    2000

    3.74

    15.30

    1.2

    77

    2500

    4.50

    18.18

    1.2

    78

     

Keywords:

Dry-type transformer

Related Products


SC (B) H15 type amorphous alloy dry transformer

Using isotropic soft magnetic conductive materials, the magnetic power is low, the resistivity is high, and eddy current losses are minimal. The core made of amorphous alloy material has very low no-load loss and no-load current, only one-third that of silicon steel sheets. The no-load loss of the transformer is 75% lower than the specified value in GB/T10228. This can significantly reduce operating costs and achieve remarkable energy savings.
< 1 >